photovoltaic array image
Connecting Solar Panels Together for Increased Power Article June 15, 2024 at 11:16 am 2024-06-15T11:16:37-04:00
alternative energy tutorials
Alternative Energy Tutorials

Connecting Solar Panels Together

How to Connect Solar Panels Together

solar powerConnecting solar panels together is a simple and effective way of increasing your solar power capabilities. Going green is a great idea, and as the sun is our ultimate power source, it makes sense to utilize this energy to power our homes. As solar power becomes more accessible, more and more homeowners are buying photovoltaic solar panels.

However, these photovoltaic solar panels can be very costly so buying them over time helps to spread the cost. But the problem then becomes how do we connect these extra solar panels together to increase the voltage and power output of what’s already there.

The trick here when connecting solar panels together is to choose a connection method that is going to give you the most energy efficient configuration for your particular requirements.

Connecting solar panels together can seem like a daunting task when you first start to look at how it should be done, but connecting multiple solar panels together is not that hard with a little thought. Wiring solar panels together in either parallel or series combinations to make larger arrays is an often overlooked, yet completely essential part of any well designed solar power system.

There are three basic but very different ways of connecting solar panels together and each connection method is designed for a specific purpose. For example, to produce more output voltage or to produce more current.

Solar photovoltaic panels can be electrically connected together in series to increase the voltage output, or they can be connected together in parallel to increase the output amperage. Solar pv panels can also be wired together in both series and parallel combinations to increase both the output voltage and current to produce a higher wattage array.

Whether you are connecting two or more solar panels, as long as you understand the basic principles of how connecting multiple solar panels together increases power and how each of these wiring methods works, you can easily decide on how to wire your own panels together. After all connecting solar panels together correctly can greatly improve the efficiency of your solar system.

Connecting Solar Panels Together in Series

The first method we will look at for connecting solar panels together is what’s known as “Series Wiring“. The electrical connection of solar panels in series increases the total system output voltage. Series connected solar panels are generally used when you have a grid connected inverter or charge controller that requires 24 volts or more. To series wire the panels together you connect the positive terminal to the negative terminal of each panel until you are left with a single positive and negative connection.

Solar panels in series add up or sum the voltages produced by each individual panel, giving the total output voltage of the array as shown.

Solar Panels in Series of Same Characteristics

connecting solar panels together in series

In this method ALL the solar panels are of the same type and power rating. The total voltage output becomes the sum of the voltage output of each panel. Using the same three 6 volt, 3.0 amp panels from above, we can see that when these pv panels are connected together in series, the array will produce an output voltage of 18 Volts (6 + 6 + 6) at 3.0 Amperes, giving 54 Watts (volts x amps) at full sun.

Now lets look at connecting solar panels in series with different nominal voltages but with identical current ratings.

Solar Panels in Series of Different Voltages

solar panels in series with different voltages

In this method all the solar panels are of different types and power rating but have a common current rating. When they are connected together in series, the array produces 21 volts at 3.0 amps, or 63 watts. Again the output amperage will remain the same as before at 3.0 amps but the voltage output jumps to 21 volts (5 + 7 + 9) .

Finally, lets look at connecting solar panels in series with completely different nominal voltages and different current ratings.

Solar Panels in Series of Different Currents

solar panels in series with different currents

In this method all the solar panels are of different types and power rating. The individual panel voltages will add together as before, but this time the amperage will be limited to the value of the lowest panel in the series string, in this case 1 Ampere. Then the array will produce 19 Volts (3 + 7 + 9) at 1.0 Ampere only, or only 19 watts out of a possible 69 watts available reducing the arrays efficiency.

We can see that the solar panel rated at 9 volts, 5 amps, will only use one fifth or 20% of its maximum current potential reducing its efficiency and wasting money on the purchase of this solar panel. Connecting solar panels in series with different current ratings should only be used provisionally, as the solar panel with the lowest rated current determines the current output of the whole array.

Connecting Solar Panels Together in Parallel

The next method we will look at of connecting solar panels together is what’s known as “Parallel Wiring“. Connecting solar panels together in parallel is used to boost the total system current and is the reverse of the series connection. For parallel connected solar panels you connect all the positive terminals together (positive to positive) and all of the negative terminals together (negative to negative) until you are left with a single positive and negative connection to attach to your regulator and batteries.

When you connect solar panels together in parallel, the total voltage output remains the same as it would for a single panel, but the output current becomes the sum of the output of each panel as shown.

Solar Panels in Parallel of Same Characteristics

connecting solar panels together in parallel

In this method ALL the solar panels are of the same type and power rating. Using the same three 6 Volt, 3.0 Amp panels as above, the total output of the panels, when connected together in parallel, the output voltage still remains at the same value of 6 volts, but the total amperage has now increased to 9.0 Amperes (3 + 3 + 3), producing 54 watts at full sun.

But what if our newly acquired solar panels are non-identical, how will this affect the other panels. We have seen that the currents add together, so no real problem there, just as long as the panel voltages are the same and the output voltage remains constant. Lets look at connecting solar panels in parallel with different nominal voltages and different current ratings.

Solar Panels in Parallel with Different Voltages and Currents

connecting solar panels together

Here the parallel currents add up as before but the voltage adjusts to the lowest value, in this case 3 volts or some voltage value very close to 3 volts. Solar panels must have the same output voltage to be useful in parallel. If one panel has a higher voltage it will supply the load current to the degree that its output voltage drops to that of the lower voltage panel.

We can see that the solar panel rated at 9 volts, 5 amps, will only operate at a maximum voltage of 3 volts as its operation is being influenced by the smaller panel, reducing its efficiency and wasting money on the purchase of this higher power solar panel. Connecting solar panels in parallel with different voltage ratings is not recommended as the solar panel with the lowest rated voltage determines the voltage output of the whole array.

Then when connecting solar panels together in parallel it is important that they ALL have the same nominal voltage value, but it is not necessary that they have the same ampere value.

Connecting Solar Panels Together Summary

Connecting solar panels together to form bigger arrays is not all that complicated. How many series or parallel strings of panels you make up per array depends on what amount of voltage and current you are aiming for. If you are designing a 12 volt battery charging system than parallel wiring is perfect. If you are looking at a higher voltage grid connected system, than you’re probably going to want to go with a series or series-parallel combination depending on the number of solar panels you have.

But for a simple reference in regards to how to connect solar panels together in either parallel or series wiring configurations, just remember that parallel wiring = more amperes, and series wiring = more voltage, and with the right type and combination of solar panels you can power just about any electrical device you may have in your home.

For more information about Connecting Solar Panels Together in either series or parallel combinations, or to obtain more information about the different types of solar panels available, or to explore the advantages and disadvantages of using solar power in your home, then Click Here to order your copy from Amazon today and learn more about designing, wiring and installing off-grid photovoltaic solar electric systems in your home.

Top Selling Solar Panel Related Products

Please Speak up!

We hope this Connecting Solar Panels Together Tutorial was useful and informative for you. Are you ready to share your thoughts
and experience with us and many others. Your comments are always welcome, just post them in the section below.

P.S. Don't forget to like, rate, and share this Alternative Energy Tutorials post. Thank you for using our website.

594 Comments already about “Connecting Solar Panels Together

  • hello administrarot.!
    i have 4 -250watts panel and i wired them in series and also i have 2 -200 Ah battries which are also wired in series and having 24 volt inverter of 3kv . so my question is that in how much time it takes to charge my battries?
    thanks in advance

  • Thanks for your excellent article on wiring solar panels. A friend and I are discussing what happens with like 24v nominal panels wired in parallel or series with an MPPT controller if one panel’s output is seriously degraded by shading. My understanding is that if wired in series current output of all panels will be reduced to that of the shaded panel. If in parallel only shaded panel’s current output will be reduced. Therefore if shading on one or more panels might be a problem best to wire in parallel. Can you confirm or not?

    • Shading, either partial or full, can greatly reduce the power output of a solar panel, and in severe cases can run the risk of hot spot formation. A photovoltaic cell in the dark behaves as a diode under forward bias acting as a short circuit.

      If connected in a series configuration, the good cells bias the shaded cell so large amounts of power is dumped into the shaded cell as shaded cells do not add to the power produced, but they absorb it. A bypass diode across the photovoltaic cell limits the voltage across it when shaded, but any bypass diodes must be rated to take total possible series current.

      Parallel shaded cells, when connected directly to a battery, will provide a short circuit discharge path for the battery. This high reverse current can be stopped by the use of a blocking diode. Blocking diodes also prevent back charging of the battery at night as the diode prevents charge coming back from the battery to the cell, or panel.

      Then if the solar panel, or array is protected by both bypass and blocking diodes, any shading will have minimal efficiency loss whatever the configuration.

  • Check out page…………Solar Infra Technologies….on Facebook

    We are looking for investors and partners for growth and expansion.

  • Hi, what would work better in charging batteries in my RV 3-100 watt panels or 1-300 watt panel?

  • I have installed three each 12v 150w 10amp solar panels. This should be 12v 450w 30amps. But the max amps i get to charge batteries at peek hours (15v while connected to batteries) is 12.5amps. this equals 12.5A×15v=187watts. Why I am not getting 450watts of power?

    • There could be a number of factors why you are not seeing full power, the panels are not receiving full sun, they maybe badly aligned, sun strength is low, or your batteries are only drawing the amount of power they required to charge. Just because your array has a potential maximum power of 450W, does not mean it will deliver 450W continuously.

  • If I connect solar panel of the same volt and amp in series to a bty of two 12 volt also connected in series,what ll happen to my eqpt

  • connecting solar panels in series or parallel increases the voltage or current respectively but do the panel embedded wiring with mc4 connectors bears the increased voltage or current? say for some 50 or 100 solar panels are connected in a combination of series or parallel?

  • I have wired 4 small solar panels, Voltage: 5V Current: 160mA, in parallel but the amps have not gone up. Help

  • Hi , I am an electrician by profession and running a small electrical contract here in Kokopo,East New Britain Province, Papua New Guinea.
    My focus now is to really know inside out of these solar systems and all its features including all its calculations .

  • I have 2 solar panels one 80 watts =17.5 V =4.571 A and the another solar panel that is 160 W =18.73 volts =8.62 A I plan on wearing them in parallel, as I believe that is my best choice correct.. which will give me 13.191 amps but will only have 17.5 volts and these will be wired to a 12 volt 30 amp /400 watt max PWM charge controller, I guess my question is losing that 1.23 volts, would it be a great loss when charging my two 6 V batteries I have in the series which is giving me 12 V to my RV thank you.

    • No, your charge controller will control the 12 volt charge to your batteries. The values you have quoted are maximum open-circuit voltage (Voc) and short-circuited current (Isc) values which will not occur if they are connected to the charge controller.

      • Actually no, I quoted the (Vmp) maximum power voltage and (Imp) Maximum power current. But anyways I should be fine then you think with putting a 160 watt solar panel in parallel with an 80 W solar panel? Thank you!

  • I would love to see a video of someone connecting the solar panels in parallel. I have 3 100 watt 12volt panels and 2 marine batteries (12 volt 135 AH and 165 AH). The batteries are connected in parallel. I have two 12 volt 30 amp controllers and a 2300 watt inverter for an off the grid system.

  • Hi
    I purchased an off grid cabin with a rudimentary solar system consisting of 3 dead 12 volt/100 watt panels. A Xantrex c35 amp charge controller, Trace 24/12 inverter and 8 200ah batteries.
    My question is I purchased 4 165watt panels to replace dead ones, they have 9.12 amp peak rating, which puts them above the rating of my ch/controller when wired in parallel. What size wire would be required to run from the panels, or could I use a 2nd ch/controller. Unfortunately the 12 volt system is what I’m stuck with fight now, is there some way to wire this setup to use all the panels. Thanks

    • Why use all four panels when three would give you what you want within the limits of the controller. The size of cable depends not only on amperage but cable length and percentage voltage drop for a DC system. The minimum you need for 12V 30A is 25mm2 (4 AWG) but this would increase with longer cable runs and lower percentage cable voltage drop, that is between 2% and 5% etc.

  • Please how to connect my 36panels 320w. 4panels in series and 9 strings in parallel. Thanks

  • Thank you very much for this information.I have read a lesent something important.I had a question though. I have one solar panel 153Watts that I am currently using to charge two 150 amp batteries that are connected in parallel. I recently bought another panel that is 153 wats. What’s is the best way to conect it with the other panel? Series or parallel and considering that my batteries are already connested in parallel would that make a difference?

    • The inter-connection of your solar panels would depend on the characteristics of your battery charge controller, series panels would give you a higher voltage, while parallel panels would give you a higher charging current.

  • What would be the optimal serial/parallel panel arrangement to address what I believe is a shading issue?

    I recently installed an interconnected-to-the-grid solar array and am noticing a significant drop in the harvested kWh.

    So this is what I have: 10 (Ten) 250-watt solar panels (open circuit voltage rated at 35 volts; all of them wired as a single serial string) 1 ThinkPower 2200 watt central inverter with max input of 13 amps and 500 volts, 1 MMP tracker

    So I had everything installed in September (I’m in the northern hemisphere); during the first days/weeks I was generating as much as 14-15 kWh per day. As year has passed I’m currently generating 5-8 kWh per day. At this rate, I’d be surprised if I’m generating more than 2-4 kWh per day at the peak of the winter.

    Here’s another piece of information that’s important: two of the panels are shaded. When the panels were installed the shading was minimum if any, but as we get closer to the winter I’m thinking the shading could be as much as 40% of these two panels during noon time.

    I was wondering if I by re-arranging the panels into several series in parallel I could isolate/optimize the array so as to minimize the degrading effect of the shading.

    Perhaps I could split my single string into two 5-panel serial strings connected in parallel hopes I may isolate the shaded two panels? Perhaps I should remove the two shaded panels altogether and stay with a serial string of 8 panels? Removing the source of the shading is not feasible (refer to this image:

    Input greatly appreciated.

    Thanks.

  • This a tech Battery Query! I have a charger/inverter all on a batt.box-80Ah! Have since secured from same vendor another 80Ah batt in an effort for longer power intervals of med. Equip. Am wanting to again expand to another batt. not from Vendor(excessive expense) Would it be detrimental to my system to olace a 100 Ah batt. in the array? Would the 100Ah ever become fully charged as do the other two from the attached solar panels(2-100watt)?
    Thanks a bunch for any aid you can send this old retired cripple! W. Basham

    • It depends on how you connect the batteries. In a series configuration the 100Ah will only charge to 80Ah. This is because as the 80Ah battery reaches its fully charged state the charging current which is common to ALL batteries in a series chain reduces to a very small trickle charge and is insufficient to full charge the 100Ah battery. In a parallel configuration however, both the 80Ah and the 100Ah batteries will charge fully.

  • In lieu of using a heavier gauge wire from my panels to my controller, I intend to use all 3 wires in a 14 gauge cord for the positive connection and all 3 in a 2nd length for the negative connection. Is this beneficial even though the 3 wires in each length are insulated from each other?

    • Doubling or trebling up of cables to carry greater currents is ok as long as they are the same diameter (gauge) and correctly terminated together at each end, whether in a single crimp connector or individually bolted together. The fact that they are individually insulated does not matter. But remember that 3 cables will carry one third of the current each, but if one cable fails the remaining two will have to carry half the current each which may exceed their rating. Also cables used for solar panels are usually double insulated to protect from mechanical damage, sun and weather exposure.

  • i have 2*70watts solar panels and a 250 watts solar panel, which charge a 12v 200Ah battery. which solar configuration will give me the shortest time to charge the battery

  • Hello. Can same solar panel be used for water pumping and electricity generation together

  • Sir
    I have learned a lot .
    I can now connect my 3 batterys in parallel to 2 solar panels .
    Now this batterys are car batterys 120 h each, is it ok ?

Leave a Comment